8 min readPacketStream
Where the public internet and a VPN are enough, where a dedicated circuit is needed, and how links inside a data center, between sites and to the cloud compare.
On this page
Link the servers in your colocation rack to a database in the public cloud over a VPN and, most of the time, it simply works. Then replication lag starts to widen only at certain hours, or bulk transfer speeds change from one day to the next, and adding bandwidth does not always fix it. Inside one data center, between data centers and out to the public cloud: what kind of connection does each of these three stretches call for?
Where the public internet and a VPN are enough
The public internet and a VPN are enough where traffic is light and latency is allowed to wobble a little. Development and test environments, management access and small backups on a long cycle all fall here. The trouble starts on stretches where volume grows and response times have to stay steady. Two responses look obvious at that point.
- Buy more internet bandwidth → Only your own segment gets wider. The other providers' networks in the middle stay as they are.
- Add VPN appliances or tunnels → Encryption throughput goes up, but the tunnels still run over the public internet.
Neither solves the path problem. AWS describes Site-to-Site VPN as an IPsec connection created over the internet. Microsoft explains that ExpressRoute, its own private connection service, offers more consistent latency than typical internet connections because it does not go over the public internet.
Public internet and VPN
- An encrypted tunnel built over the internet
- The path crosses several providers' networks, so congestion is out of your hands
- Fits stretches with light traffic where latency can wobble a little
Dedicated circuit
- Connects the two endpoints without crossing the public internet
- Can reduce latency variation caused by congestion on the public internet
- Fits stretches with heavy volume where response times must stay steady
Think of ordinary roads and a dedicated lane. On an ordinary road your arrival time depends on the traffic around you, however good your car is. On the public internet, packets likewise cross several providers' networks in turn, and you have no control over congestion on those segments. How to measure latency from Korean carrier networks to your server is covered in the PacketStream Pulse article.
Once you have decided you need a dedicated circuit, the next question is which kind.
Which endpoints are you connecting?
Choose the connection based on what you need to connect. Use Cross Connect for a physical link within one data center or Metro Connect to link two data centers in the Seoul metropolitan area. If one endpoint is a public cloud, Cloud Connect extends the connection to the cloud provider’s point of presence.
| Criterion | Cross Connect | Metro Connect | Cloud Connect |
|---|---|---|---|
| Stretch | Inside one data center | Between data centers in the Seoul metro area | From a rack in the data center to a public cloud |
| Layer | L1 physical link | Dedicated L2 (Ethernet) on a DWDM backbone | L2 or L3 interconnection |
| Bandwidth | 1G to 400G, by port | Up to 100 Gbps per link | 100 Mbps to 10 Gbps |
| Redundancy | Single or dual path | Unprotected or Protected | Single or dual path |
| What sets the price | Data center, number of connections | The two data centers, bandwidth, redundancy | Cloud provider, data center, bandwidth, redundancy |
The layer tells you how much of the connection the provider takes on. L1 is the cable itself, L2 is the delivery of Ethernet frames and L3 is IP routing. The higher the layer, the more the provider handles; the lower the layer, the more you decide yourself. Start with a connection inside one data center.
Cross Connect: a physical link inside one data center
Cross Connect is an L1 link that joins two pieces of equipment in the same data center directly with a cable. From your rack you can reach a carrier or an IX, another customer's equipment in the same building, or another rack of your own. No routing equipment sits in between, so of the three connections this path is the simplest.
Three cable media are supported, and the media on offer differ by data center.
Cross Connect cable media
- SMF fiber
- MMF fiber
- Copper (Cat6)
If physical separation matters for your security requirements, also look at a separate patch panel, armored cable on request and a secured meet-me room (MMR).
Metro Connect: dedicated Layer 2 between data centers
Metro Connect links data centers across the Seoul metro area over dedicated L2 (Ethernet). Equipment in two separate data centers behaves as if it were plugged into one switch, so you keep running your IP addressing and routing the way you already do. Traffic between the data centers stays off the public internet.
Transport runs on a DWDM (Dense Wavelength Division Multiplexing) backbone. DWDM carries several wavelengths on a single fiber and uses each wavelength as an independent channel. You can choose Point-to-Point, which joins two sites, or Multipoint, where several sites share one L2 network. Bandwidth per link is one of the four options below, and you can scale beyond that with LAG (Link Aggregation).
Metro Connect bandwidth per link
- 1 Gbps
- 10 Gbps
- 40 Gbps
- 100 Gbps
Metro Connect is mainly used in three setups.
- Backbone between data centers: joins the networks of two data centers into one.
- Separating production and disaster recovery (DR): keeps the production site and the DR site in different data centers.
- Data replication: replicates data between data centers.
Reaching a public cloud from here takes one more step.
Cloud Connect: a dedicated circuit to the public cloud
Cloud Connect links your colocation rack in the data center to a public cloud over a dedicated circuit. Each cloud provider has its own private connection service, and Cloud Connect supports the four below.
Private connection services supported by Cloud Connect
- AWS Direct Connect
- Azure ExpressRoute
- Google Cloud Interconnect
- Oracle FastConnect
AWS explains that Direct Connect lets you connect to AWS services while bypassing internet service providers in your network path.
Port bandwidth is 100 Mbps, 1 Gbps or 10 Gbps, on a dedicated or a shared port. Both L2 and L3 interconnection are supported. Cloud providers' private connection services exchange routes over BGP. AWS lists 802.1Q VLAN and BGP support among the requirements for Direct Connect, and Microsoft likewise explains that ExpressRoute exchanges routes over BGP. With an L2 handoff you run the routing toward the cloud on your own equipment, so whether your team can operate BGP becomes the deciding factor.
For all three connections, if there is only one path, everything stops when that path is cut.
Redundancy is counted in paths
Redundancy is measured not by the number of circuits but by the number of independent paths. Two circuits that run through the same duct can be cut by a single accident. All three connections let you choose between a single path and a dual path, and the choice determines what happens during a failure.
Single path
- Unprotected on Metro Connect, single path on Cloud Connect
- If the path is cut, traffic stops until it is restored
- Fiber recovery on Metro Connect is completed within 6 hours
- Fits backup transfers that can run a few hours late
Dual path
- Protected on Metro Connect, Redundant Link on Cloud Connect
- On a failure, traffic fails over to the second path automatically
- Fits stretches that carry real-time replication or service traffic
The test is how long your service can hold out with this connection down.
The level of redundancy is set by the weakest segment. Microsoft builds every ExpressRoute circuit from two connections and, for maximum resiliency, recommends placing two circuits in two different peering locations. Even when the cloud side is prepared this way, a single router in your rack remains a single point of failure. The redundancy you choose also shows up in the price.
What sets the price
Each connection is priced on different factors.
- Cross Connect: charged as a monthly fee plus a setup fee per connection. The price differs by data center, and within one data center it is the same for every cable type.
- Metro Connect: no fixed price list. Quoted individually on the two data centers, bandwidth and redundancy.
- Cloud Connect: no fixed price list. Quoted individually on the cloud provider, data center, bandwidth and redundancy.
For Metro Connect and Cloud Connect, the values you set yourself are bandwidth and redundancy, and you need your normal and peak transfer volumes to set either one.
The order for choosing a connection
For a direct physical link between two devices in the same data center, consider Cross Connect. For a connection beyond the data center, work through these questions in order.
- Is a VPN over the internet enough?Check normal and peak traffic and how much latency variation the workload can tolerate. If the existing VPN meets those requirements, there is no need to add a dedicated circuit.
- Which endpoints need a dedicated connection?Consider Metro Connect between data centers in the Seoul metropolitan area, or Cloud Connect between your rack and a public cloud.
- Tolerable downtimeChoose a single or a dual path by how long the service can hold out, and bring the equipment in your rack up to the same level.
- Layer and operating scopeDecide whether you will run the routing yourself, and if you need encryption, add a VPN on top of the dedicated circuit.
Where there are two or more stretches, chain the connections. Metro Connect is also used for hybrid cloud integration, so if the route to the cloud passes through another data center, consider it together with Cloud Connect.
Replication lag at a particular time of day does not, on its own, tell you what caused it. First check whether latency along the network path also rose when replication slowed.
Related products
More insights
All insights
Where to Run GPU Servers: Data Center Requirements and Three Ways to Deploy
GPU servers do not drop straight into a standard server rack. What to check on power, cooling and networking, and how renting, building and colocation differ.Perspectives9 min read

DDoS Mitigation: How to Measure Attacks and What to Ask Before You Choose
DDoS mitigation means telling attack traffic from legitimate traffic. We cover L3/L4 and L7 attacks, bps, pps and rps, Always-On vs On-Demand, WAFs, questions to ask first and the order of response.Perspectives6 min read

What Is a VPS? What to Check First When Choosing a Virtual Server
From what a VPS is and how it differs from shared hosting to choosing CPU, memory and storage, traffic billing and backups. The criteria you need when choosing a virtual server for the first time.Perspectives8 min read
Ready to get started?
Tell us about your workload and we will help you choose the right products and plans.
Talk to our team
Questions about anything you read here? Our team will help.
Contact SalesInsights
Where PacketStream is heading, what we learn running the network, and the latest product news and notices.
All insights